![]() USB type B mini-connect or, HID device class X 2 using optional probes, range 32 ☏ to 122 ☏ (0☌ to +50.0 ☌) ![]() ± 201 "H20 from calibration pressure, (± 500mbar)ĥv DC external power supply and internal charging circuitĪBS / Polypropylene with Silicon Rubber Insertsīuilt-in gas dryer tube to remove moisture ± 2.0% Full Scale over operating temperature rangeġ Conditions during factory calibration, typically 25 ☌, 980 mBar ± 1.0% Full Scale constant temperature and pressure Pressure dependence: ± 0.02% of reading / hPa (typical at 5% CO2) Temperature dependence: ± 0.2% reading (typical at 5% CO2) Viasensor G100-11N CO2 (0-20%) Incubator Analyzer with O2 (0-100%) and RH Probeīy custom dual wavelength infra-red with reference channelĪccuracy: ± (1% of range + 2% of reading) at reference conditions 1 Viasensor G150-00N - changes the CO2 sensor to measure 0-10,000ppm Viasensor G110-00N - changes the CO2 sensor to measure 0-100% Viasensor G100-10N - adds O2 Sensor to measure from 0-100% Viasensor G100-00N - Only measures CO2 from 0-20% Viasensor G100-01N - adds a 15mm RH Probe Looking for other measurements or CO2 ranges? Check out these configurations below. The Viasensor G100-11N includes the following: Please Note: Viasensor also recommends users to self calibrate the unit roughly once a month using the optional G-CALKIT Calibration Kit (Calibration gas sold separately). Viasensor backs this incubator analyzer with a 1 year warranty. The G100-11N has ports for two temperature probes that can be purchased separately. The internal pump has a flowrate of roughly 100 cc/min and features a built-in gas dryer tube that removes moisture. The Viasensor G100-11N is lightweight and has an easy to read LCD display with LED backlight when needed. The included RH Probe is 15mm diameter with an option for 4mm diameter if needed. ![]() Monitoring CO2, O2 and atmospheric levels in incubators is crucial to the successful growth of cell cultures and embryos and having a simple to operate analyzer is vitally important. Quick verification of CO2 incubator levelsīy utilizing CO2 IR technology, the Viasensor G100-11N has greatly improved accuracy and response time compared to traditional chemical methods.CO2 is measured by a custom dual wavelength infra-red sensor with reference channel and O2 is measured with an internal electrochemical cell that has an approximate 3 year lifetime in air. Viasensor G100-11N CO2 (0-20%) Incubator Analyzer with O2 (0-100%) and RH Probe monitors CO2 and O2 for verifying incubators in the IVF, research, medical, and pharmaceutical markets.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |